Bracing - CMU Wall Temporary Support
Created a CMU bracing plan for construction in an area susceptible to high winds. Erection was defined by Initial Period, Intermediate Period, and Final Period. Guidelines were established for each period based on wall configuration and anticipated wind loads. Procedures and recommendations were summarized in a CMU bracing plan.